1 / 6
QuickStat-TC
INSTALLATION AND OPERATION MANUAL
A
F
2
GENERAL INFORMATION
Use of this Manual
This manual covers the installation and operation of the Raychem
QuickStat-TC thermostat and must be used with the following
documents:
QuickNet System Installation Manual (H57704)
CeraPro System Installation Manual (H58956)
Important: For the Pentair Thermal Management warranty
and agency approvals to apply, the instructions included in this
manual and product packages must be followed.
Features
The QuickStat-TC is an electronic thermostat that must be used
with the Raychem QuickNet floor heating mats and CeraPro floor
heating cables.
QuickStat-TC provides the following features:
Integrated Class A, Ground-Fault Circuit Interrupter (GFCI).
Operates at 120 V, 208 V, and 240 V at 60 Hz
Switches on your heating system at predetermined times on
different days of the week.
Offers 4 periods each day that you can set at different
temperatures.
Comes with a preprogrammed schedule that is suitable for most
installations. However, you can customize this program any time
you wish.
Allows you to reset the thermostat to factory settings.
Changes the start time of a heating period automatically so that
the desired temperature is reached at the time that you set.
Multiple temperature control options so users can control the
system based on floor temperature (F), ambient air temperature
(A), or both (AF).
On/Off switch to turn off thermostat during summer months.
KIT CONTENTS
Item Qty Description
A 1 QuickStat-TC thermostat
B 2 Mounting screws
C 1 Floor temperature sensor 15 ft (4.6m)
D 5 Wire nuts
E 1 Screwdriver
A
C
B
E
D
APPROVALS
TECHNICAL DATA
Supply voltage 120 V, 208 V, 240 V, 60 Hz
Maximum switching current 15 A
GFCI Class A, 5 mA trip level
Ambient setpoint range 40°F to 86°F (5°C to 30°C)
(A/AF mode)
Floor setpoint range (F mode) 40°F to 104°F (5°C to 40°C)
Floor limit setpoint range 40°F to 104°F (5°C to 40°C)
(AF mode)
Operating temperature range 32°F to 120°F (0°C to 50°C)
Storage temperature range –4°F to 120°F (–20°C to 50°C)
THERMAL BUILDING SOLUTIONS
EN-RaychemQuickStatTCthermostat-IM-H5851710/14
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - QuickStat-TC

1 / 6QuickStat-TCINSTALLATION AND OPERATION MANUALAF2GENERAL INFORMATIONUse of this ManualThis manual covers the installation and operation of the Ray

Page 2 - Wiring the thermostat

SOLUTIONS DE CONSTRUCTION THERMIQUECF-RaychemQuickStatTCthermostat-IM-H5851710/144/6Programmation Le QuickStat-TC est livré avec un horaire pr

Page 3

SOLUTIONS DE CONSTRUCTION THERMIQUE5/6CF-RaychemQuickStatTCthermostat-IM-H5851710/14Mode Vacances Danscemode,leQuickStat-TCestàlatem

Page 4

6 / 6CF-RaychemQuickStatTCthermostat-IM-H5851710/14WWW.PENTAIRTHERMAL.COM© 2009-2014 Pentair. 400-115-052Pentair, QuickNet, CeraPro et QuickSta

Page 5 - Vacation Mode

THERMAL BUILDING SOLUTIONSEN-RaychemQuickStatTCthermostat-IM-H5851710/142 / 6 Important: This thermostat must be installed according to all rele

Page 6 - THERMAL BUILDING SOLUTIONS

THERMAL BUILDING SOLUTIONSEN-RaychemQuickStatTCthermostat-IM-H5851710/143 / 6Thermostat Controls and DisplayThe following figure shows the the

Page 7

THERMAL BUILDING SOLUTIONSEN-RaychemQuickStatTCthermostat-IM-H5851710/144 / 6ProgrammingThe QuickStat-TC comes with a pre-programmed default sch

Page 8 - Câblage du thermostat

THERMAL BUILDING SOLUTIONSEN-RaychemQuickStatTCthermostat-IM-H5851710/145 / 6Vacation Mode In this mode, the QuickStat-TC is set to the Vacati

Page 9

6 / 6WWW.PENTAIRTHERMAL.COM© 2009-2014 Pentair. 400-115-052NORTH AMERICA PENTAIR THERMAL MANAGEMENT LLC Tel: +1.800.545.6258Fax: +1.800.527.5703Tel:

Page 10 - Mode manuel

SOLUTIONS DE CONSTRUCTION THERMIQUE1 / 6QuickStat-TCInstructIons d'InstallatIon et d'opératIonCF-RaychemQuickStatTCthermostat-IM-H58517

Page 11 - Mode Vacances

SOLUTIONS DE CONSTRUCTION THERMIQUECF-RaychemQuickStatTCthermostat-IM-H5851710/142/6Important : L'installation de ce thermostat doit être

Page 12

SOLUTIONS DE CONSTRUCTION THERMIQUE3/6CF-RaychemQuickStatTCthermostat-IM-H5851710/14Thermostat Controls and DisplayLagureci-dessousillus

Commentaires sur ces manuels

Pas de commentaire